Yokogawa CA71/SP1

$974,00

In stock

SKU: CA71/SP1 Category: Tag:

Simultaneous signal generation and measurement capability: The CA71 lets you handle regular tests on TCs, RTDs and various other types of sensors and instruments, as well as operation checks when a problem has occurred (TC and RTD measurement functions are CA71 only.)

  • Includes Options: Communications cable, data logging software, 120V power supply, Magnetic backing instrument case, source/measure cables, and NIST traceable certification
  • Comprehensive source/measure instruments for all your calibration and equipment checking needs at maintenance sites
  • Sensors and instruments require a wide variety of operation checks in the field
  • Small, lightweight, multifunction calibrator that can simultaneously source and measure voltage, current, resistance, TC, RTD, frequency, and pulse signals
  • Simultaneous signal generation and measurement capability: Lets you handle regular tests on TCs, RTDs and various other types of sensors and instruments, as well as operation checks when a problem has occurred
  • AC voltage (including supply voltage) measurement capability: In cases where numerous signal converters and other devices are mounted on a rack or panel, the Handy Calibrator can be used to check the input and output signals of each device, while simultaneously checking the power supply
  • Source: Values set in steps of 4-20 mA, 24V DC Power supply to transmitter
  • Online communication: RS-232C-compliant optically isolated interface
  • Divided output (n/m) function: Output settings are divided (n/m), eliminating the need for bothersome calculations for percentage output
  • Auto step function: Changes the output value in step form based on the setting from the divided output (n/m) functions
  • Changes can be generated automatically every 10% or 25%
  • Sweep functions: Linearly raises or lowers the output
  • The raising/lowering time can be set to either 16 or 32 seconds
  • Memory function: Source values and measurements forming individual value sets can be saved to or loaded from the Handy Calibrators internal memory (maximum 50 value sets)
  • Easy operation: The Handy Calibrator incorporates rotary switches for simple handing
  • Just open the carrying case cover and connect the cables, and youre ready to take measurements

>

Each Unit Includes

  • Source Signal Lead Cables (One Red, Two Black) 98020
  • Measurement Lead Cables (One Red, One Black) RD031
  • Carrying Case 93016
  • Terminal Adapter 99021
  • Users Manual
  • Fuse: A1501EF (for current terminal input protection)
  • Four AA Alkaline Batteries
  • Communications Cable
  • Data logging software
  • Power Supply
  • Magnetic backing instrument case
  • Source/Measure Cables
  • NIST Traceable Certification

Main Menu

Yokogawa CA71/SP1