-
1 × $115,00
-
1 × $10.431,00
-
2 × $378,00
-
1 × $162,00
-
1 × $1.940,00
-
1 × $17.195,00
-
1 × $316,00
-
1 × $769,00
-
1 × $406,00
-
1 × $3.727,00
-
1 × $1.180,00
-
1 × $5.643,00
-
1 × $71,00
-
1 × $4.297,00
-
1 × $1.573,00
-
1 × $215,00
-
1 × $4.292,00
-
1 × $90,00
-
1 × $1.179,00
-
1 × $3.334,00
-
1 × $0,00
-
1 × $78,00
-
1 × $0,00
-
1 × $1.847,00
-
1 × $13.252,00
-
2 × $4.394,00
-
1 × $248,00
-
1 × $67,00
-
1 × $7.216,00
-
1 × $21,00
-
1 × $6.309,00
-
1 × $2.205,00
-
1 × $6.229,00
-
1 × $774,00
-
1 × $210,00
-
1 × $513,00
-
1 × $6.618,00
-
1 × $2.223,00
-
1 × $282,00
-
1 × $5.480,00
-
1 × $564,00
-
1 × $30,00
-
1 × $222,00
-
1 × $872,00
-
1 × $5.779,00
-
1 × $3.267,00
-
1 × $310,00
-
1 × $4.753,00
-
1 × $577,00
Roll over image to zoom in
Sonel Test Measurement MRU-200 GPS
$1.639,00
THE MRU-200-GPS OFFERS A VARIETY OF MEASUREMENT METHODS FOR GROUND RESISTANCE AND RESISTIVIY.
The MRU-200-GPS is the only meter which can perform all ground resistance measurement methods, 2-pole, 3-pole, 4-pole, and impulse earth impedance methods.
- Ground resistance using auxiliary electrodes, or with electrodes and clamp for measurements in the presence of multiple ground paths
- Ground resistance using double clamps when it is not possible to use auxiliary electrodes
- Impulse ground resistance without disconnecting measured grounding
- Soil resistivity using Wenner method
- Leakage current using current clamp or flexible Rogowsky probe
- Measurement of continuity of equipotential bonding and protective conductors (meets IEC 60364-6-61:2000 section 6.12.2) with auto-zero function and 200 mA current
- Ground resistance measurement, with 2-pole, 3-pole, or 4-pole methods
- Leakage current measurement
- Selective measurement with clamp excludes influence from parallel ground points
- No opening of rusted conductors needed
- Impulse ground resistance measurement at 4/10 µs, 8/20 µs, or 10/350 µs
- Two clamps resistance measurement method without auxiliary test probes
- GPS coordinates of measurement location are stored with test results
- Resistance measurement of auxiliary electrodes
- Measurement of interference voltage and interference frequency
- Measurement in the presence of interference voltages at 162/3 Hz, 50 Hz, 60 Hz, and 400 Hz
- Automatic or manual selection of frequency of measuring signal
- Selection of maximum measuring voltage (25 V and 50 V)
- Distance between the electrodes noted in meters (m) and feet (ft)
- Memory storage for 990 measurements
- Calibration information of test clamp(s)
- Real-time clock
- USB interface for PC connection
- Internal battery with indication of state of charge
- Backlit LCD graphic display
- Double insulated meets IEC 61010-1 and IEC 61557 standards CAT IV 300 V