1 × $5.459,00
-
1 × $2.693,00
-
1 × $188,00
-
1 × $3.608,00
-
1 × $64,00
-
1 × $2.966,00
-
1 × $401,00
-
1 × $662,00
-
1 × $718,00
-
1 × $26.821,00
-
1 × $2.890,00
-
1 × $7.891,00
-
1 × $1.714,00
-
1 × $1.612,00
-
1 × $3.386,00
-
1 × $1.847,00
-
1 × $393,00
-
1 × $2.274,00
-
1 × $2.826,00
-
1 × $101,00
-
1 × $162,00
-
1 × $2.501,00
-
1 × $218,00
-
1 × $1.390,00
-
1 × $2.257,00
-
1 × $1.539,00
-
1 × $277,00
-
2 × $35,00
-
1 × $3.120,00
-
1 × $876,00
-
1 × $823,00
-
1 × $1.102,00
-
1 × $2.855,00
-
1 × $89,00
-
1 × $5.249,00
-
1 × $2.718,00
-
1 × $3.026,00
-
1 × $98,00
-
1 × $1.256,00
-
1 × $2.890,00
-
1 × $2.445,00
-
1 × $530,00
-
1 × $5.779,00
-
1 × $752,00
-
1 × $2.886,00
-
1 × $2.522,00
-
1 × $1.573,00
-
1 × $9.832,00
-
1 × $2.900,00
-
1 × $6.301,00
-
1 × $2.966,00
Roll over image to zoom in
Sonel Test Measurement MIC-10S1
$2.415,00
The MIC-10s1 is a portable, rugged, easy-to-use, 10kV class insulation test meter. The MIC-10s1 has a wide measurement range, selectable test voltages, and excellent safety features.
- Insulation resistance to 40.0 TΩ
- User-selectable test voltage any from 50 V to 1,000 V (with 10 V resolution) and 1,000 V to 10,000 V (with 25 V resolution)
- Continuous indication of measured insulation resistance or leakage current
- Audio beeps every five-second periods to indicate measurement progress
- Indication of actual test voltage during measurement
- 1.2 mA, 3 mA and 5 mA test current
- Step voltage and ramp voltage insulation resistance measurements (SV) (RV)
- Selectable test times (T1, T2 , T3 from 1 to 600 seconds) to measure one or two absorption coefficients
- Adjustable measuring time to 99 59’
- Polarization index (PI) and dielectric absorption ratio (DAR) measurements
- Dielectric Discharge calculation (DD)
- Digital filters function for measurements in high-noise environment (10 s, 30 s , 60 s)
- High-noise immunity, up to 1550 V (induced)
- Adjustable limit settings for measured resistance RISO
- Measurement of capacitance during the measurement of RISO
- DC and AC voltage measurement in the range of 0 V to 600 V
- Graphical display of R and V, or R and I, plots the progress of test in real-time, and final graph (see example below)
- Meter conforms to EN 61557
>
Safety First:
- CAT-IV 600V, CAT-III 1000V
- Automatic discharge of tested object after measurement completes to remove high voltage charges remaining on cable
- Protection against measuring live objects, measurement will not proceed
- Measurements with test leads up to 180 ft / 55 m length
>
Construction:
- Backlit keyboard and graphical display
- Rugged IP 54 case protected from water spray from any direction
>
Power Supply:
- Built-in battery pack, low battery warning indicator, built-in fast charger
- AC power: 90 V to 260 V, 50 Hz / 60 Hz
>
Memory:
- 990 cells of memory (11,880 records) to save test results
- Wireless data transmission to a PC with Bluetooth®, or via USB cable