No products in the cart.
Roll over image to zoom in
Megger BAKER NETEP W/O SERVER LICENSE 4VB
$12.141,00
- Without server license
- Monitors motor systems for any degradation of performance, poor power quality and adverse load conditions
- Built upon the proven motor system monitoring technologies of the Baker EXP4000 Dynamic Motor Analyzer
- Features proprietary data collection mechanisms that are coupled with standardized computer server and network technologies
- Operates with a single voltage measurement connection per voltage bus (up to 7 different voltage busses per single NetEP unit), and current sensors installed for each motor being monitored
- Continuously monitors and analyzes more than 120 electrical parameters on up to 32 motors, compares results to user-defined thresholds and generates alerts if these threshold limits are crossed
- Two data acquisition methods are provided: power quality (acquired every ten seconds) and time waveforms (acquired once per hour)
- Tracks motor on/off cycles, determines load mismatches and identifies any adverse load oscillations or overloads
- Generates alerts for environmental factors such as excessive heat on a given motor